TyshakX
Presentational Presentational

Percutaneous Transluminal Valvuloplasty (USA)

TYSHAK® Line

TYSHAK® balloon catheters were designed in collaboration with Prof Mike Tynan and Prof Shakeel Qureshi.  They are designed with a low profile that delivers high performance. Manufactured from a micro-thin, non-compliant balloon material, these innovative balloon catheters require small introducers. The reduced sheath size helps minimize vessel trauma and entry-site complications. A short, flexible distal tip provides superior maneuverability. With well-defined shoulders and balloon tapers, TYSHAK® catheters glide easily through smaller and difficult-to-negotiate vessels. They are available in a range of diameters (2.0-30.0mm) and lengths (1.0-10.0cm). 

Unique Benefits

TYSHAK® PTV balloons are coaxially constructed with a non-compliant balloon for correct inflation size. The balloon is made of a micro-thin material which allows for an exceptionally low profile, requires the smallest introducers possible, and has extremely fast inflation and deflation times. The distal shaft through the balloon is highly flexible for maximum trackability. This, combined with the pushability of the coaxial shaft, provides outstanding tracking performance.

The catheter bodies are Polymeric, DEHP-free, and not made with natural rubber latex. The balloons are a thermoplastic elastomer; non-compliant - which will not exceed +/- 10% of the labeled balloon size at RBP or nominal pressure, are DEHP-free, and not made with natural rubber latex.

TYSHAK®: Specifications, Instructions for Use, and Forms

Balloon Diameters (mm):  2.0-25.0
Balloon Lengths (cm):  1.0-10.0
Rated Burst Pressure (ATM): 1.5-10
Introducer Size (FR):  4-11
Indication:  PTV of the Pulmonary Valve

TYSHAK IFUs:
US: IFU-102BA
CANADA: RM0344-01J
INTERNATIONAL: RM0344-01J

Post Market Surveillance Form

TYSHAK II®: Specifications, Instructions for Use, and Forms

Lower profile and lower-rated burst pressure (RBP) than TYSHAK®

Balloon Diameters (mm):  4.0-30.0
Balloon Lengths (cm):  2.0-10.0
Rated Burst Pressure (ATM): 1.5-6
Introducer Size (FR):  4-10
Indication:  PTV of the Pulmonary Valve

TYSHAK II IFUs:
US: IFU-105BA
CANADA: RM0344-03L
INTERNATIONAL: RM0344-03L

Post Market Surveillance Form

TYSHAK X™: Specifications, Instructions for Use, and Forms

The X-line version has a radiopaque braided inner tubing, which possesses extra high inner-lumen strength for increased pushability.

Balloon Diameters (mm):  8.0-25.0
Balloon Lengths (cm):  2.0-6.0
Rated Burst Pressure (ATM): 1.5-5
Introducer Size (FR):  6-11
Indication:  PTV of the Pulmonary Valve

TYSHAK-X IFUs:
US: IFU-102XB
CANADA: RM0344-02J
INTERNATIONAL: RM0344-02J

Post Market Surveillance Form

TYSHAK NuCLEUS®: Specifications, Instructions for Use, and Forms

The TYSHAK NuCLEUS® catheter is suitable for PTV and pre-dilatation in transcatheter pulmonary heart-valve replacement procedures.  The balloon is designed with a waist formed into the middle of the balloon.  Upon reaching a specified pressure, the waist will expand between 90% to almost 100% of the rated balloon diameter.

The innovative balloon design of the TYSHAK NuCLEUS® facilitates positive positioning while holding the balloon in the correct location prior to, and during, inflation.

The TYSHAK NuCLEUS® requires a smaller introducer and has lower RBPs than NuCLEUS™.

Balloon Diameters (mm):  4.0-25.0
Balloon Lengths (cm):  2.0-4.0
Rated Burst Pressure (ATM): 2-5
Introducer Size (FR):  6-11
Indication:  PTV of the Pulmonary Valve

TYSHAK-NuCLEUS IFUs:
US: IFU-103B
CANADA: RM0344-54G
INTERNATIONAL: RM0344-54G

PMCF Tyshak NuCLEUS

Balloon Diameter (mm) Balloon Length (cm) Introducer (FR) Shaft Size (FR) Usable Length (cm) Guide Wire (inches) Rated Burst Pressure (ATM) Maximum Volume (cc) Catalog Number Product
9.0 3.00 5 5.0 100 0.025 3.5 SN008 TYSHAK II
9.0 3.00 6 5.0 70 0.018 5.0 PDC116 TYSHAK
9.0 3.00 6 5.5 70 0.025 5.0 PDC180 TYSHAK
9.0 3.00 6 5.5 70 0.035 5.0 PDC026 TYSHAK
9.0 3.00 6 5.5 100 0.035 5.0 TN016 TYSHAK NUCLEUS
9.0 4.00 6 5.5 100 0.035 5.0 TN017 TYSHAK NUCLEUS
9.0 4.00 6 5.5 100 0.035 5.0 PDC086 TYSHAK
10.0 2.00 5 5.0 90 0.025 3.5 SO003 TYSHAK II
10.0 2.00 6 5.5 85 0.025 5.0 PDC010 TYSHAK
10.0 2.00 6 5.5 85 0.035 5.0 PDC064 TYSHAK
10.0 2.00 6 5.5 100 0.035 5.0 PDC114 TYSHAK
10.0 2.00 7 6.0 100 0.035 5.0 PDC181 TYSHAK
10.0 2.00 7 6.0 100 0.035 5.0 TN018 TYSHAK NUCLEUS
10.0 3.00 5 5.0 90 0.025 3.5 PDC506 TYSHAK II
10.0 3.00 5 5.0 100 0.025 3.5 SN009 TYSHAK II
10.0 3.00 6 4.0 70 0.018 5.0 PDC130 TYSHAK
10.0 3.00 6 5.5 70 0.025 5.0 PDC163 TYSHAK
10.0 3.00 6 5.5 100 0.035 5.0 PDC117 TYSHAK
10.0 3.00 6 6.0 80 0.025 5.0 PDC081 TYSHAK
10.0 3.00 6 6.0 100 0.025 5.0 PDC080 TYSHAK
10.0 3.00 7 6.0 85 0.025 5.0 PDC164 TYSHAK
10.0 3.00 7 6.0 100 0.035 5.0 TN019 TYSHAK NUCLEUS
10.0 3.00 7 6.0 100 0.035 5.0 PDC011 TYSHAK
10.0 3.00 7 6.0 100 0.035 5.0 PDC110 TYSHAK
10.0 4.00 5 5.0 90 0.025 3.5 SO001 TYSHAK II
10.0 4.00 6 5.5 70 0.025 5.0 PDC044 TYSHAK
10.0 4.00 6 5.5 100 0.025 5.0 PDC053 TYSHAK
10.0 4.00 6 5.5 100 0.035 5.0 PDC182 TYSHAK
10.0 4.00 7 6.0 100 0.035 5.0 TN020 TYSHAK NUCLEUS
10.0 4.00 7 6.0 100 0.035 5.0 PDC012 TYSHAK
10.0 5.00 5 5.0 90 0.025 3.5 SO031 TYSHAK II
10.0 5.00 6 5.0 70 0.025 5.0 PDC132 TYSHAK
10.0 5.00 6 5.5 85 0.025 5.0 PDC089 TYSHAK
10.0 5.00 7 6.0 100 0.035 5.0 PDC047 TYSHAK
10.0 6.00 6 5.5 100 0.025 5.0 PDC055 TYSHAK
10.0 6.00 6 5.5 100 0.035 5.0 PDC054 TYSHAK
10.0 6.00 6 6.0 100 0.025 3.5 SO009 TYSHAK II
10.0 6.00 7 6.0 100 0.035 5.0 PDC183 TYSHAK
10.0 8.00 6 5.0 100 0.025 5.0 PDC146 TYSHAK
10.0 8.00 7 6.0 100 0.025 5.0 PDC074 TYSHAK
10.0 8.00 7 6.0 100 0.035 5.0 PDC129 TYSHAK
10.0 10.00 7 6.0 100 0.025 5.0 PDC075 TYSHAK
10.0 10.00 7 6.0 100 0.035 5.0 PDC090 TYSHAK
11.0 2.00 5 5.0 90 0.025 3.5 SN11290 TYSHAK II
11.0 2.00 5 5.0 90 0.025 3.5 SO086 TYSHAK II
11.0 3.00 5 5.0 90 0.025 3.5 SO017 TYSHAK II
11.0 3.00 6 5.0 70 0.018 4.5 PDC150 TYSHAK
11.0 3.00 7 6.0 100 0.035 4.5 PDC159 TYSHAK
11.0 4.00 5 5.0 90 0.025 3.5 SO002 TYSHAK II
12.0 2.00 5 5.0 90 0.025 3.5 SO008 TYSHAK II

Disclaimer

All products are subject to individual country regulations in regards to the importation and/or sale of these products. Refer to Instructions for Use for a complete listing of indications, contraindications, warnings, and precautions.

 

NuMED for Children

9100 Conroy Windermere Rd - Suite 200
Windermere, FL
34786 USA
Tel: 407-352-5200

 

NuMED Inc.

2880 Main Street
Hopkinton, NY
12965 USA
Tel: 315-328-4491

 

NuMED Canada

45 Second Street West
Cornwall, Ontario
K6J1G3 CANADA
Tel: 613-936-2592