WORLD LEADER IN PEDIATRIC CARDIOLOGY

     

TYSHAK-X
Percutaneous Transluminal Valvuloplasty catheter

Our X-Line catheters exhibit several special features:

Xtra high inner lumen strength

Xtra fast guidewire movement (even with balloon inflated)

Increased pushability from new braided inner tubing

Radiopaque inner tubing

TYSHAK-X Specifications

Balloon
Diameter
(MM)

Balloon
Length
(CM)

Introducer
Size
(FR)

Shaft
Size
(FR)

Usable
Length
(CM)

Guide
Wire
(Inches)

Rated
Burst
(ATM)

Catalog
No.

8

2

6

6

100

0.035

5.0

PDC300

8

3

6

6

100

0.035

5.0

PDC301

8

4

6

6

100

0.035

5.0

PDC302

8

5

6

6

100

0.035

5.0

PDC303

8

6

6

6

100

0.035

5.0

PDC304

9

2

6

6

100

0.035

5.0

PDC305

9

3

6

6

100

0.035

5.0

PDC306

9

4

6

6

100

0.035

5.0

PDC307

9

5

6

6

100

0.035

5.0

PDC308

9

6

6

6

100

0.035

5.0

PDC309

10

2

6

6

100

0.035

5.0

PDC310

10

3

6

6

100

0.035

5.0

PDC311

10

4

6

6

100

0.035

5.0

PDC312

10

5

6

6

100

0.035

5.0

PDC313

10

6

6

6

100

0.035

5.0

PDC314

12

2

7

6

100

0.035

4.5

PDC315

12

3

7

6

100

0.035

4.5

PDC316

12

4

7

6

100

0.035

4.5

PDC317

12

5

7

6

100

0.035

4.5

PDC318

12

6

7

6

100

0.035

4.5

PDC319

14

3

8

7

100

0.035

3.5

PDC320

14

4

8

7

100

0.035

3.5

PDC321

14

5

8

7

100

0.035

3.5

PDC322

14

6

8

7

100

0.035

3.5

PDC323

15

3

8

7

100

0.035

3.5

PDC324

15

4

8

7

100

0.035

3.5

PDC325

15

5

8

7

100

0.035

3.5

PDC326

15

6

8

7

100

0.035

3.5

PDC327

16

3

8

7

100

0.035

3.5

PDC328

16

4

8

7

100

0.035

3.5

PDC329

16

5

8

7

100

0.035

3.5

PDC330

16

6

8

7

100

0.035

3.5

PDC331

18

3

9

8

100

0.035

2.0

PDC332

18

4

9

8

100

0.035

2.0

PDC333

18

5

9

8

100

0.035

2.0

PDC334

18

6

9

8

100

0.035

2.0

PDC335

20

3

10

8

100

0.035

2.0

PDC336

20

4

10

8

100

0.035

2.0

PDC337

20

5

10

8

100

0.035

2.0

PDC338

20

6

10

8

100

0.035

2.0

PDC339

22

3

10

9

100

0.035

2.0

PDC340

22

4

10

9

100

0.035

2.0

PDC341

22

5

10

9

100

0.035

2.0

PDC342

22

6

10

9

100

0.035

2.0

PDC343

25

3

11

9

100

0.035

1.5

PDC344

25

4

11

9

100

0.035

1.5

PDC345

25

5

11

9

100

0.035

1.5

PDC346

25

6

11

9

100

0.035

1.5

PDC347

The devices listed have CE mark approval.  Any customer or distributor outside of the EU will be subject to their individual country's regulations in regards to the importation and sale of these products.

This publication could include technical or other inaccuracies or typographical errors. Changes are periodically added to the information herein; these changes will be incorporated in the new editions of the publication. NuMED Incorporated may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.

 

 